Abstract

Reports on the presence of digoxin-like immunoreactive substance(s) (DLIS) in the plasma and urine of several animal species and a few human test subjects prompted us to undertake to confirm the presence of DLIS in plasma and urine of normal persons and to investigate some characteristics of this antibody-DLIS binding. For this purpose we used a modified radioimmunoassay kit involving antidigoxin antibody-coated test tubes and 125I-labeled digoxin to measure DLIS in urine and concentrated plasma of ostensibly healthy subjects. In 12 separate experiments with plasma the mean sensitivity was 5.12 (SD 1.11) pg per tube, expressed as digoxin. There was no significant cross reactivity with human serum albumin in concentrations up to 200 g/L. The mean DLIS value (in digoxin equivalents) for plasma from 24 normal subjects was 33.58 (SD 14.24) ng/L. Its mean concentration in urine from five subjects was 315.00 (SD 91.38) ng/L.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.