Abstract

Using four different digoxin kits, it was disclosed that the majority of various samples including amniotic fluid, cord blood, and serum from neonates contained substantial levels of digoxin-like immunoreactive substance. The differences in data seemed to be due to the range of epitopes which are recognized by antidigoxin antiserum. The day-to-day studies on sera serially obtained from infants at birth to 48 days old revealed that the level of the substance (0.31 +/- 0.12 ng/ml) in sera of the 1-day-old neonates rapidly declined to the level of 0.1 ng/ml by the 2nd postnatal wk and thereafter gradually declined. The immunological specificity and accuracy of the detection of digoxin-like immunoreactive substance was confirmed by a sample dilution test, a recovery test for standard digoxin, and an absorption test with antidigoxin antiserum. The amniotic fluid and cord blood also contained four to eight times more of a digitoxin-like immunoreactive substance than they did digoxin-like immunoreactive substance. A significant correlation was observed between the levels of digoxin-like immunoreactive substance and of digitoxin-like immunoreactive substance (p less than 0.01).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.