Abstract

Compared to the conventional boost power factor correction (PFC) converter, a totem-pole bridgeless PFC has high efficiency because it does not have an input diode rectifier stage, but a current spike may occur when the polarity of the grid voltage changes. This paper proposes a digital control algorithm for bridgeless totem-pole PFC with a simple control structure based on the phase angle of grid voltage. The proposed algorithm has a PI-based double-loop control structure and performs DC-link voltage and input inductor current control. Rectifying switches operate based on the proposed rectification algorithm using phase angle information calculated through a single-phase phase-locked loop (PLL) to prevent current spikes. The feed-forward duty ratio value is calculated according to the polarity of the grid voltage and added to the double-loop controller to perform appropriate power factor control. The performance and feasibility of the proposed control algorithm are verified through a 3 kW hardware prototype.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call