Abstract
Objective: The objective of this in vitro study was to evaluate the volumetric wear of three CAD/CAM (computer-aided design/computer-aided manufacturing) ceramic materials. Materials and Methods: The materials evaluated were CEREC Blocs (Dentsply Sirona), Initial LRF (GC) and Amber Mill (HASS Corp). All the samples (n=30) were subjected to simulated brushing (100,000 cycles). The wear was assessed by superimposing pre- and post-brushing scans obtained with an intraoral optical scanner (CEREC Primescan; Dentsply Sirona, Germany), which was then imported into the OraCheck 5.0 software (Dentsply Sirona, Germany). Results: The CAD/CAM ceramic materials tested showed no statistically significant differences in terms of the average volumetric wear (p-= 0.455). Conclusion: Therefore, it can be concluded that the ceramic materials have a good behavior under simulated brushing, without significant volumetric alterations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.