Background: To investigate the accuracy and reproducibility of digital measurements of Little’s Irregularity Index and to evaluate if different degrees of dental crowding could influence these measurements. Methods: The study included 40 dental models and 5 sub-groups were created according to the severity of the crowding. In both the digital models and the study cast, Little’s Irregularity Index was recorded by measuring (1) the mesiodistal width of each tooth and (2) the arch lengths in both the maxillary and mandibular jaw. Two operators performed measurements on plaster and digital models using, respectively, a digital caliper and OrthoAnalyzerTM 3D software (3Shape A/S, Copenhagen, Denmark). Statistical analysis was performed to assess intra- and inter-operator variability, the accuracy between manual and digital measurements and if the amount of crowding could affect the accuracy of the digital measurements. Results: Concerning intra-examiner reliability, no statistically significant differences were detected (p > 0.05). In the maxillary and mandibular arch, the Intraclass Correlation Coefficient (ICC) value was 0.996 and 0.997 for the analogic measurements and 0.998 and 0.978 for the digital measurements. For the maxillary arch, the mean difference between the analogic and digital Little’s Irregularity Index (LII) measurements was 0.43 mm while for the mandibular arch the mean difference was 0.24 mm, showing some overestimation of the digital measurements (p < 0.05). No differences were found according to crowding subgroups (p > 0.05). Conclusions: Digital measurements of LII could be considered as a valid substitute of the gold standard analogical measurement.

Highlights

  • Study models allow clinicians to carry out space analysis and to evaluate the discrepancy in tooth size and arch length by using Bolton’s ratio and other parameters such as Little’s Irregularity Index (LII)

  • Digital measurements of LII could be considered as a valid substitute of the gold standard analogical measurement

  • Findings from our study demonstrated that the differences between the analogic and digital measurements were significant, especially for maxillary arches with a mean difference of 0.43 mm (p ≤ 0.01), whereas differences were lower in the mandibular arch (0.24 mm) (p ≤ 0.05)

Read more

Summary

Introduction

Study models allow clinicians to carry out space analysis and to evaluate the discrepancy in tooth size and arch length by using Bolton’s ratio and other parameters such as Little’s Irregularity Index (LII). To investigate the accuracy and reproducibility of digital measurements of Little’s Irregularity Index and to evaluate if different degrees of dental crowding could influence these measurements. Methods: The study included 40 dental models and 5 sub-groups were created according to the severity of the crowding. In both the digital models and the study cast, Little’s. The mean difference between the analogic and digital Little’s Irregularity Index (LII) measurements was 0.43 mm while for the mandibular arch the mean difference was 0.24 mm, showing some overestimation of the digital measurements (p < 0.05). No differences were found according to crowding subgroups (p > 0.05)

Methods
Discussion
Conclusion