Abstract

An automated digital image subtraction technique for temporally sequential chest images has been developed in order to aid radiologists in the detection of interval changes. A number of small regions of interest (ROIs) are selected automatically in the lung areas of two temporally sequential chest images. A local matching, based on a cross-correlation method, is performed on each pair of corresponding ROIs in order to determine shift values for the coordinates of two images. A proper warping of x,y coordinates is obtained by fitting two-dimensional polynomials to the distributions of shift values. One of the images is warped and then subtracted from the other. Forty six pairs of chest images (42 with interval changes and 4 without interval change) were processed using this method. The subtraction images were able to enhance various important interval changes, such as differences in the size of tumor masses, changes in heart size, and changes in pulmonary infiltrates or pleural effusions. Approximately 70% of the pairs showed reasonably good registration.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.