Abstract

Current controlled inverter using hysteresis controller is popular due to the simplicity of the algorithm implementation with a robust dynamic response. However, the controller action requires the use of analogue circuitry to maintain its characteristics which lacks the interfacing, maintenance, flexibility, and integration of a digital system. In this paper, a digital hysteresis controller based on sampling the feedback signal and applying control action at a fixed interval is investigated. The controller is applied on three proposed configurations for a single phase grid connected inverter with a designed LCL filter and a primary control loop on the filter inductor current. Parameters affecting the hysteresis controller primary characteristics are investigated and a selection criteria of filter parameters is derived. To eliminate performance issues arising from parameters mismatching and variable switching frequency, adaptive hysteresis band calculation and a secondary control loop is proposed. By means of simulation and experimental implementation, the performance of the configurations is evaluated.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.