Abstract

Diffusion-weighted (DW) MRI at 1.5 T was carried out in two groups of patients. MRI data were correlated with the biopsy and histopathology (where available). The performance of two sequences -- a single-shot FSE (14 patients) and a single-shot EPI (15 patients) -- was compared. Average ADC values from the normal peripheral zone (PZ), central gland (CG) and the tumour [prostate carcinoma (PCa)] were calculated from b values of 0 and 600. Tukey-Kramer test was used for statistical analysis. EPI produced higher values of ADC (10(-3) mm(2)/s) than FSE sequence: 1.992+/-0.208 vs. 1.573+/-0.270 in PZ (P<.001), 1.518+/-0.126 vs. 1.373+/-0.179 in CG and 1.214+/-0.254 vs. 0.993+/-0.158 in PCa (P<.01). In conclusion, both EPI and FSE sequences showed differences in ADC between normal PZ, CG and PCa; however, EPI produced significantly higher ADC values than FSE.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.