Abstract

To compare diffusion-weighted (DW) and T2-weighted MR imaging in detecting colorectal liver metastases in a rat model, using histological examination as a reference method. Eighteen rats had four liver injections of colon cancer cells. MR examinations at 7T included FSE-T2-weighted imaging and SE-DW MR imaging (b = 0, 20 and 150s/mm(2)) and were analysed by two independent readers. Histological examination was performed on 0.4-mm slices. McNemar's test was used to compare the sensitivities and the Wilcoxon matched pairs test to compare the average number of false-positives per rat. One hundred and sixty-six liver metastases were identified on histological examination. The sensitivity in detecting liver metastases was significantly higher on DW MR than on T2-weighted images (99/166 (60%) (reader 1) and 92/166 (55%) (reader 2) versus 77/166 (46%), P ≤ 0.001), without an increase in false-positives per rat (P = 0.773/P = 0.850). After stratification according to metastasis diameter, DW MR imaging had a significantly higher sensitivity than T2-weighted imaging only for metastases with a diameter (0.6-1.2mm) similar to that of the spatial resolution of MR imaging in the current study. This MR study with histological correlations shows the higher sensitivity of DW relative to T2-weighted imaging at 7T for detecting liver metastases, especially small ones. • Diffusion weighted (DW) sequences are increasingly used in magnetic resonance imaging (MRI). • DW has higher sensitivity for liver metastases than T2-weighted imaging at 7T. • This increase in sensitivity is especially marked for small liver metastasis detection. • This higher sensitivity is confirmed in an animal model with histological correlation. • DW imaging has the potential for earlier diagnosis of small liver metastases.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call