Abstract

Portland cement was mixed with different concentrations of radium chloride (1200, 2400 and 3600 Bq) to produce radioactive sources. These sources were surrounded with cement of different thickness (1, 2 and 4 cm). The release of radon from these sources (before and after being surrounded) was studied. The results showed that radon release from the sources itself was less then its release from the same source after being surrounded by cement, and the release did not change with the thickness of cement. Samples were covered with a thin layer of polyethylene before being surrounded with cement. It was found that this additional layer reduced the radon exhalation. This thin layer stopped any reaction between the source and the surrounding cement during solidification of the cement layers. These reactions are thought to be the reason for the increase of radon exhalation from the sources surrounded by cement.