Abstract

Depth profiles of ion-implantation induced defect centers have been investigated by cross-sectional CL measurements in the energy range from visible to near infrared. CL observation has shown that point defects diffused out from implanted region to ~10 µm depth during activation annealing. Annealing temperature dependence of the depth distribution of CL intensity of these defects has suggested that structural transformation of point defects proceeds as “silicon vacancy (VSi) → carbon vacancy-antisite pair (VC-CSi ; UD2) → antisite pair (CSi-SiC ; DI)”.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.