It is shown that diffusion-weighted imaging is possible in the human breast. Diffusion constants were measured in the breast parenchyma of four volunteers with no known breast lesions. The apparent diffusion constant of water measured in regions of interest chosen in normal human breast fibroglandular tissue was 1.64 +/- 0.19 x 10(-5) cm2/S and that measured in the area of fatty breast tissue was 0.32 +/- 0.18 x 10(-5) cm2/S. The resulting images indicate that fibroglandular tissue and fat can be clearly distinguished in diffusion-weighted as well as in absolute diffusion images of the breast. Potential future applications of this technology for the study of breast pathologies are suggested.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.