Abstract
In this research paper, we report an eco-friendly diffuse reflectance infrared fourier transform spectroscopic (DRIFTS) method for quantifying neratinib. The systematic method development was performed as per the recent analytical quality by design concept. The critical method variables such as resolution (cm-1) and the total number of scans were investigated using a central composite design to determine their influence on the measurements at 2204.64 cm-1. The method was valid over a linear (R2 > 0.99) range of 5-30 µg mg-1 of neratinib, with adequate accuracy (recovery > 100 %) and precision (RSD < 1%). Afterwards, the method greenness assessment was performed using the Analytical Greenness Metric and White Analytical Chemistry approach to establish the overall green sustainability of the current method. In a nutshell, the different functional groups of the drug were identified, and neratinib was quantified from the pharmaceutical tablets with optimum method robustness.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.