Abstract
Diffuse reflectance infrared Fourier transform (DRIFT) spectroscopy was used to characterize the product of each step in the preparation of a silica-immobilized N-hydroxysuccinimide (NHS) active ester. The preparation of this NHS active ester linkage was based on a literature procedure for the immobilization of proteins. The DRIFT method was used to guide modification of this literature procedure. The DRIFT method also was used to indicate an impurity entrapped in the 60-Å diameter pores of the silica support during the formation of the immobilized active ester. Degradation of the immobilized NHS active ester, stored under either argon or dioxane, can be followed by the DRIFT method. Myoglobin and glycine were allowed to react with the active ester, and the result for this silica support was evaluated by the DRIFT method. Elemental analysis was used to provide information on the loading of the silica-immobilized moities that were presented for DRIFT analysis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.