Abstract

PurposeThis study aimed to evaluate the ability of susceptibility-weighted imaging (SWI) to detect cortical venous reflux (CVR) in patients with intracranial non-cavernous dural arteriovenous fistulas (DAVFs), which can be helpful to differentiate benign and aggressive DAVFs. Material and MethodsTwenty-seven patients (8 women and 19 men) with 33 non-cavernous DAVFs were divided into benign and aggressive groups. Presence of CVR and pseudophlebitic pattern (PPP) and location of fistula on SWI were determined. Digital subtraction angiography was used as the reference standard. Interobserver agreement for the presence of CVR and PPP and location of DAVF on SWI was evaluated using the kappa statistic. Statistical comparisons between the benign and aggressive DAVFs were performed. ResultsSensitivity, specificity, positive predictive value, and negative predictive value of SWI for detecting CVR was 73.7%, 85.7%, 87.5%, and 70.6%, respectively. Corresponding values for detecting PPP were 95.2%, 83.3%, 95.2%, and 83.3%, respectively. SWI correctly identified DAVF location in 78.9%. Prevalence rates of CVR and PPP on SWI were significantly higher in aggressive DAVFs than benign ones. ConclusionSWI exhibited high sensitivity and specificity for detection of CVR, a characteristic used to differentiate benign and aggressive lesions. CVR and PPP on SWI are signs of aggressive DAVFs that guide to perform angiography confirmation and prompt treatment to avoid serious complication.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call