To assess MR-based radiomic analysis in preoperatively discriminating small (< 2 cm) pancreatic ductal adenocarcinomas (PDACs) from neuroendocrine tumors (PNETs). A total of 197 patients (146 in the training cohort, 51 in the validation cohort) from two centers were retrospectively collected. A total of 7338 radiomics features were extracted from T2-weighted, diffusion-weighted, T1-weighted, arterial phase, portal venous phase and delayed phase imaging. The optimal features were selected by the Mann-Whitney U test, Spearman's rank correlation test and least absolute shrinkage and selection operator method and used to construct the radiomic score (Rad-score). Conventional radiological and clinical features were also assessed. Multivariable logistic regression was used to construct a radiological model, a radiomic model and a fusion model. Nine optimal features were identified and used to build the Rad-score. The radiomic model based on the Rad-score achieved satisfactory results with AUCs of 0.905 and 0.930, sensitivities of 0.780 and 0.800, specificities of 0.906 and 0.952 and accuracies of 0.836 and 0.863 for the training and validation cohorts, respectively. The fusion model, incorporating CA19-9, tumor margins, pancreatic duct dilatation and the Rad-score, exhibited the best performance with AUCs of 0.977 and 0.941, sensitivities of 0.914 and 0.852, specificities of 0.954 and 0.950, and accuracies of 0.932 and 0.894 for the training and validation cohorts, respectively. The MR-based Rad-score is a novel image biomarker for discriminating small PDACs from PNETs. A fusion model combining radiomic, radiological and clinical features performed very well in differentially diagnosing these two tumors. A fusion model combining MR-based radiomic, radiological, and clinical features could help differentiate between small pancreatic ductal adenocarcinomas and pancreatic neuroendocrine tumors. Preoperatively differentiating small pancreatic ductal adenocarcinomas (PDACs) and pancreatic neuroendocrine tumors (PNETs) is challenging. Multiparametric MRI-based Rad-score can be used for discriminating small PDACs from PNETs. A fusion model incorporating radiomic, radiological, and clinical features differentiated small PDACs from PNETs well.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.