Abstract

Deployment of SSDs in enterprise settings is limited by the low erase cycles available on commodity devices. Redundancy solutions such as RAID can potentially be used to protect against the high Bit Error Rate (BER) of aging SSDs. Unfortunately, such solutions wear out redundant devices at similar rates, inducing correlated failures as arrays age in unison. We present Diff-RAID, a new RAID variant that distributes parity unevenly across SSDs to create age disparities within arrays. By doing so, Diff-RAID balances the high BER of old SSDs against the low BER of young SSDs. Diff-RAID provides much greater reliability for SSDs compared to RAID-4 and RAID-5 for the same space overhead, and offers a trade-off curve between throughput and reliability.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.