Abstract

To achieve a reliable and accurate liquid level detection, a differential pressure based liquid level measuring instrument is proposed in this paper. The phase-sensitive demodulation of the signal is performed by discrete Fourier transform through microcontroller. Pressure measurement in both DC and AC stimulation provides means to study and compare proposed instrument reliability and robustness not only in steady state condition but also in case of experiencing turbulence on the surface of the liquid. Good linearity in both AC and DC has been observed. As results show, AC based level sensing demonstrated reliable and robust level detection to compare with DC in both steady state condition and experiencing turbulence on the surface.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.