This article presents an in-service noninvasive fault diagnosis (FD) routine to detect incipient stator's interturn failure (ITF) in the direct torque control (DTC) driven induction motors. The developed FD routine is based on the application of the mathematical morphological gradient (MMG) technique on the stator currents. Being a time-domain technique, it is less computational burdensome than the frequency-domain-based FD. To detect the faulty phase, we introduced and implemented the differential MMG (ΔMMG) algorithm concept. A comprehensive electromagnetic investigation of harmonics and interharmonics contents due to the ITF, the DTC controller's reaction, the inverter's switching activity is presented. A design guideline of selecting the structuring element length in the FD routine was introduced. A physics-based cosimulation platform was built to investigate the feasibility of the proposed FD algorithm. The simulation reinforced by the experimental results depicted the robustness of the FD method. The comparative analysis is presented between the developed ΔMMG and the conventional motor current signature analysis (MCSA). The experimental results proved that developed FD is faster and more robust than the MCSA in detecting the ITFs at their embryonic stages.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.