Abstract

A differential fiber Bragg grating (FBG) sensor with a free active element bulk-modulus for high-pressure (or displacement) measurement is presented. Based on the differential measurement method and an isosceles triangle cantilever structure, problems of cross-sensitivity and chirped signal in FBG sensor are improved both theoretically and experimentally. Preliminary experiments indicate that temperature-compensated measurement results agree well with the theoretical analysis. Displacement measurement sensitivity is ∼1.75 pm/ μm , and the estimated pressure measurement resolution can reach 0.27 MPa in case the wavelength shift measurement resolution is 0.01 nm .