Abstract
The authors' work deals with the calculation of the fire resistance of pre-stressed hollow panels. The thermal characteristics of air in the hollows were determined on the basis of testing the fire resistance of two Spiroll panels, thickness 250 mm, with hollows with circle section. The thermal characteristics of the air in the hollows were used to compare the fire resistance of similar pre-stressed panels with different hollows, thickness 200 mm; Echo with hollows with oval section and Elematic with hollows with circle section. Furthermore the fire resistance is analysed in term of the concrete cover; a smaller concrete cover responds to a higher load-bearing capacity for a permanent design situation but decreases the final fire resistance. The calculated fire resistance is compared with the fire resistance determined by testing, if the results are available.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.