Abstract

Five signal processing techniques were applied to ratio spectra for quantitative determination of bisoprolol (BIS) and hydrochlorothiazide (HCT) in their binary mixture. The proposed techniques are Numerical Differentiation of Ratio Spectra (ND-RS), Savitsky–Golay of Ratio Spectra (SG-RS), Continuous Wavelet Transform of Ratio Spectra (CWT-RS), Mean Centering of Ratio Spectra (MC-RS) and Discrete Fourier Transform of Ratio Spectra (DFT-RS). The linearity of the proposed methods was investigated in the range of 2–40 and 1–22μg/mL for BIS and HCT, respectively. The proposed methods were applied successfully for the determination of the drugs in laboratory prepared mixtures and in commercial pharmaceutical preparations and standard deviation was less than 1.5. The five signal processing techniques were compared to each other and validated according to the ICH guidelines and accuracy, precision, repeatability and robustness were found to be within the acceptable limit.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.