Abstract

In neurosurgery, posterior approaches intended at the craniovertebral junction are frequently used. The most popular procedures for treating upper cervical instability are C1 lateral mass, C2 pedicle, and C1-C2 transarticular screw stabilization. Due to their proximity to neural structures and the presence of the high-riding vertebral artery (VA), these techniques are complicated. The risk of VA damage can be decreased by mobilizing the VA. Using cadaveric specimens in this study was aimed to demonstrate C2 pedicle and C1-C2 transarticular screw placement with VA mobilization and a novel C2 inferior corpus screw placement technique. In this study, twelve adult cadaveric specimens and two adult dry cadaveric C2 bones were used with the permission and decision of the University Research Ethics Committee. Colored silicone was injected into the arteries and veins of these twelve cadaveric specimens. Then, muscle dissection was performed stepwise, and the C2 vertebrae of the cadavers were revealed with a surgical microscope. Each specimen and entire stages of the dissections were recorded photographically. After cadaver dissections, screw placement was performed with three different techniques. Finally, radiological imaging was done with fluoroscopy. After dissection, the lateral mass of the C2 vertebra was observed, and lateral to it, the transverse process and foramen were detected with the help of a hook. Next, the posterior wall of the VA groove was removed using a 1 mm thin plate Kerrison rongeur until the VA loop could partially be observed the VA. This enables us to find the top of the loop of the VA and mobilize it inferiorly using a dissector. Following this step, the C1-2 transarticular, C2 pedicle, and the novel C2 inferior corpus screw placement can be performed safely by directly visualizing the artery. Due to the nearby neurologic and vascular structures, placing the C2 pedicle and C1-2 transarticular screw is a challenging procedure, especially in high-riding VA cases. However, it is possible to place the C2 pedicle, C1-2 transarticular, and novel C2 inferior corpus screw after the mobilization of the VA. This study aimed to show all of them together on a cadaver for the first time, to understand the anatomy of the C2 vertebra, and to use screw placement techniques to minimize the risk of complications.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.