Abstract

To test for gender differences in the measurements obtained by Segami and Quantitative Gated SPECT (QGS) software programs. 181 asymptomatic individuals without heart disease were submitted to myocardial perfusion imaging. End-diastolic volumes (EDV), end-systolic volumes (ESV) and left ventricular ejection fraction (LVEF) were measured by QGS and Segami software programs to evaluate the influence of gender, age, weight, height, heart rate, systolic blood pressure, diastolic blood pressure, body mass index and body surface area. The means in the QGS method were: EDV (women= 68 ml; men= 95 ml; p<0.001), LVEF (women= 66.24%; men= 58, 7%) and Segami: EDV (women= 137 ml; men= 174 ml), LVEF (women= 62.67%; men= 58, 52%). There were significant differences between men and women in the EDV (p<0.001), ESV (p<0.001) and LVEF (p=0.001) that persisted after adjusting for body surface area. Ventricular volumes were significantly lower and LVEF was significantly higher in women, estimated by QGS or Segami software programs.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.