Abstract

The broadband dielectric measurement method based on the vector network analysis technique, in combination with an open-ended coaxial probe, was applied to the determination of the dielectric relaxation behaviour of one- and two-component backfilling grout materials in the frequency range from 40 MHz to 2 GHz. The cement hydration process and the gelling of commercial grouts was monitored in real-time to investigate the application of non-destructive testing methods in the tunnelling industry. It was found that the time-dependent dielectric relaxation behaviour can accurately reveal the different stages of the hydration process and delineate the start of gel hardening. These measurement results demonstrate the practicability of the real-time dielectric measurement method to determine the broadband dielectric parameters of conventional backfill materials used in underground construction to determine construction integrity using non-destructive testing methods.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.