Abstract
The conventional Sawyer-Tower circuit is modified so as to employ a quasi-DC electric-field rather than the 60Hz AC electric-field. By using this modified Sawyer-Tower method, the P-E hysteresis loop can be determined using 1 cycle of electric field. This technique enables the samples to avoid the joule heating induced breakdown, which often occurred under the cyclic load of the 60 Hz AC electric-field. As the quasi-DC electric-field was used in this study, it is very important to compensate the phase shift by the lossy conduction during measurement. A novel method of compensation is also to be presented.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.