Abstract

We have discussed dielectric characteristics of liquid nitrogen (LN/sub 2/)/polypropylene (PP) laminated paper composite insulation system for the practical electrical insulation design of high temperature superconducting (HTS) cables. Focusing on the partial discharge (PD) inception characteristics and mechanism, the volume effect and its saturation on PD inception electric field strength (PDIE) was evaluated at atmospheric and pressurized condition. PD inception characteristics under lightning impulse voltage application were also investigated using an electrical and optical PD measuring system, and compared with those under ac voltage application.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.