Abstract
The dielectric strength of GFRPs (glass-fiber-reinforced plastics) under combined application of electrical and mechanical stresses was investigated in liquid He, liquid N/sub 2/, and silicone oil at room temperature. With the combined application of tensile and electrical stresses in cryogenic liquids, the dielectric breakdown of GFRPs occurred prior to mechanical breakdown when the applied electrical stress was lower than the DBS (dielectric breakdown strength) of GFRPs without tensile stress. In the case of tensile stress application under constantly applied electrical stress, the DBS and GFRPs decreased markedly. The reason for the large DBS decrease of GFRPs was the occurrence of microcracks in matrix resins because of their brittleness at cryogenic temperatures. Combining GFRP with polyimide film in cryogenic liquids lessened the decrease in DBS. Compared with tensile stress application, the influence of compressive stress on the DBS of GFRPs was very small.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.