Abstract

The time-dependent dielectric breakdown has been investigated in Co–Fe–B/MgO/Co–Fe–B junctions by voltage ramp experiments and focused on its dependence on the barrier thickness, junction area, polarity of the applied voltage, ramp speed, and annealing temperature. The results suggest that the breakdown voltage strongly depends both on the polarity of the applied voltage and the annealing temperature. Magnetic tunnel junctions (MTJs) with positive bias on the top electrode show higher breakdown voltage than MTJs with negative bias. We found that there is a significant decrease in the breakdown voltage when the annealing temperature is increased above 350 °C.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.