Abstract

AbstractAfter extensive experiments aimed at determining the free volatile fatty acids (C2 to C6) in organically highly polluted percolation water of household refuse dumping places there proved optimum a column packed with 10% Carbowax 20 M on Chromatron N‐AW‐DMCS after having been conditioned for five days at 270°C and subsequently covered with 10% hard wax. On short retention times the investigated isomeric column pairs are completely separated. Equally favourable results were obtained also for liquid manure and silage extracts. The detection limits lie between 10 and 20 mg/l, the relative standard deviation is 20 … 30% in the range of the lower detection limit and 2 … 3% at 200 mg/l in the upper range. In the investigation of percolation waters with concentrations between 235 and 4300 mg/l reproducibility lies at a mean relative standard deviation of 0.5 … 2.8%. The technique is well suited for routine checking.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.