Abstract

Baroreflex dysfunction is common in chronic heart failure and contributes to the associated sympathoexcitation. Baroreceptor activity normally decreases during volume unloading, causing an increase in sympathetic outflow and resulting in forearm vasoconstriction. Some heart failure patients develop attenuated vasoconstriction or paradoxical vasodilation. The mechanism for this is unknown. We have recently demonstrated diastolic ventricular interaction in some patients with chronic heart failure as evidenced by increases in left ventricular (LV) end-diastolic volume in association with decreases in right ventricular (RV) volume during volume unloading. We reasoned that such an increase in LV volume, by increasing LV mechanoreceptor activity, would decrease sympathetic outflow and could therefore explain the abnormal vascular responses seen in such patients. We assessed changes in forearm vascular resistance (FVR) during application of -20 and -30 mm Hg lower-body negative pressure (LBNP) in 24 patients with chronic heart failure and 16 control subjects. Changes in LV and RV end-diastolic volumes were assessed during -30 mm Hg LBNP in all heart failure patients. Diastolic ventricular interaction was demonstrated in 12 patients as evidenced by increases in LV end-diastolic volume in association with decreases in RV end-diastolic volume during LBNP. Changes in FVR during LBNP (-20 and -30 mm Hg) were markedly attenuated in these 12 patients (-1.6+/-11.2 and -0.9+/-12.5 U) compared with both the remaining patients (11.9+/-10.0 and 17.0+/-12.3 U) and the control subjects (16.5+/-9.5 and 23.1+/-13.9 U) (P<.01 for both comparisons at each level of LBNP). FVR decreased in 5 of these 12 patients during -30 mm Hg LBNP, a response seen in none of the remaining patients (P=.01). Diastolic ventricular interaction in patients with chronic heart failure is associated with attenuated forearm vasoconstriction or paradoxical vasodilation during LBNP. This may explain the apparent derangement in baroreflex control of sympathetic outflow during acute volume unloading in heart failure.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.