Abstract

The paper presents the diagnostics of the technical condition of the external layers of the sports hall walls. Structural failures related to construction defects themselves constitute a relatively small percentage (4.1% in 2017, 5.05% in 2014-2017 [1]), although the main reason for them is the lack of maintaining technological rigors (76.9% in 2017, 68.4% in 2014-2017 [1]). The presented and described case study of the technical condition of the newly built sports hall does not refer to structural failure, but to the reduction of the risk of that failure as a result of non-compliance with construction technology, in particular, in relation to the external walls. Contrary to the design, the walls of the sports hall were made of aerated concrete. According to the declaration of a designer, the contractor neither consulted the changes with the designer nor gain the acceptance of the designer for using aerated concrete instead of the primary proposed and designed brick structure. In addition, aerated concrete curtain walls with a height of about 4.5 m were made without any wall connectors. This resulted in a risk of a structure failure involving the collapse of its curtain walls. The technological requirements for the repairing of the elements of supporting walls as well as the diagnostic process of the other damaged finishing cladding of external walls are also provided in this paper.

Highlights

  • The article presents a case study of the diagnostics of the technical condition of the external layers of the sports hall walls

  • The proposals for removing physical defects have been provided, along with determining the scope of necessary construction works necessary to bring the building into the proper technical condition in accordance with applicable regulations and civil engineering experiences and to eliminate abovementioned structural failure

  • The value of construction repair works related to the repair of curtain walls in the variant with the use of fasteners connecting the wall layers as well as the removal of curtain walls and their further reconstruction were similar

Read more

Summary

Introduction

The article presents a case study of the diagnostics of the technical condition of the external layers of the sports hall walls. The proposals for removing physical defects have been provided, along with determining the scope of necessary construction works necessary to bring the building into the proper technical condition in accordance with applicable regulations and civil engineering experiences and to eliminate abovementioned structural failure. These issues are important for a wide selection of building technologies and materials to create durable and affordable repairing projects and construction works [3,4,5,6] in our climate zone, taking into account the inconvenience of these repair works

Description of the technical condition of the building
Repairing of damaged external walls
Repairing of the flashings
Repairing of the plasters on the façades
Repairing of the clinker claddings of the retaining wall and basement walls
Repairing of the roofing
Findings
Discussion
Conclusions