Abstract

This paper deals with condition monitoring and vibration diagnostics of vertical sulphuric acid pumps running in continuous long term operation mode. The task of experimental testing and theoretical modeling – to increase reliability and efficiency of vertical pumps through elimination of rotor lateral vibration. On the basis of experimental testing results analysis the dynamic model was designed and simulated. The reason of high vibration of the pump rotor is the rotor technological bow and cavitation phenomenon that take place in the pump.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.