Abstract

To investigate whether the small bowel transit time (SBTT) influences the diagnostic yield of capsule endoscopy (CE). Six hundred and ninety-one consecutive CE procedures collected in a database were analyzed. SBTT and CE findings were recorded. A running mean for the SBTT was calculated and correlated to the diagnostic yield with a Spearman's correlation test. Subgroup analyses were performed for the various indications for the procedure. There was a positive correlation between the diagnostic yield and SBTT (Spearman's rho 0.58, P < 0.01). Positive correlations between diagnostic yield and SBTT were found for the indication obscure gastrointestinal bleeding (r = 0.54, P < 0.01), for polyposis and carcinoid combined (r = 0.56, P < 0.01) and for the other indications (r = 0.90, P <0.01), but not for suspected Crohn's disease (r = -0.40). The diagnostic yield in small bowel capsule endoscopy is positively correlated with the small bowel transit time. This is true for all indications except for suspected Crohn's disease.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.