Abstract

Introduction: Calculation of the bone dimensions is of great importance for implant treatment. Several radiographic modalities have been used for this purpose. This study compared the accuracy of mesiodistal measurements of bone using panoramic radiography, cone beam computed tomography (CBCT), and the clinical methods. Methods: In this descriptive cross-sectional study, panoramic and CBCT images were obtained from 100 implant patients. Mesiodistal bone dimensions (distance between tooth CEJ in the mesial of edentulous region and CEJ of the tooth in distal of edentulous region) were calculated using a scaled ruler on the orthopantomograms and the system software in the CBCT images. During the implant insertions, a mucoperiosteal flap was raised and clinical dimensions of the bone were measured by a periodontal probe and bone gauge. The differences of bone height and thickness measurements between gold standard and CBCT or panoramic modalities were analyzed using Student’s t- test. Results: The mean bone height was 10.64±1.55, 11.44±1.51, and 10.68±1.6 mm in the clinical, panoramic and CBCT modalities, respectively. Statistically significant difference was noted between the clinical and panoramic techniques ( P 0.05). During the bone height calculations, 79%, 62% and 78% of the images were ranked in the normal range using CBCT, panoramic and gold standard measurements, respectively. The mean areas under the ROC curve were 0.92 and 0.83 in CBCT and panoramic techniques, respectively. Conclusion: Accuracy of the CBCT images was higher than panoramic technique in measuring the bone dimensions and this technique can be confidently used to calculate the bone dimensions for the implant surgeries. Keywords: Partially edentulous jaw; panoramic radiography; cone-beam computed tomography; bone dimensions

Highlights

  • Calculation of the bone dimensions is of great importance for implant treatment

  • This study compared the accuracy of mesiodistal measurements of bone using panoramic radiography, cone beam computed tomography (CBCT), and the clinical methods

  • Diagnostic value of imaging modalities in determining the mesiodistal bone dimensions compared to the gold standard

Read more

Summary

Introduction

Calculation of the bone dimensions is of great importance for implant treatment. Several radiographic modalities have been used for this purpose. During the bone height calculations, 79%, 62% and 78% of the images were ranked in the normal range using CBCT, panoramic and gold standard measurements, respectively. Conclusion: Accuracy of the CBCT images was higher than panoramic technique in measuring the bone dimensions and this technique can be confidently used to calculate the bone dimensions for the implant surgeries. Various radiographic techniques (plain X-ray, computed tomography, etc) have been suggested prior to the implant treatment. Ideal techniques such as CT scan are available for determining the exact bone dimensions before the implant placement, researchers are still searching for a cheaper, widely accessible technique with a reasonably low radiation dose

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call