Abstract

The aims of this study were (1) to evaluate FDG PET/CT and CT for the detection of axillary lymph node metastases in breast cancer (BC) patients and (2) to evaluate FDG PET/CT as a pre-test for the triage to sentinel lymph node biopsy (SLNB) versus axillary lymph node dissection (ALND). The sensitivity, specificity, positive and negative predictive value (PPV, NPV), and accuracy of FDG PET/CT and CT for axillary lymph node metastases were determined in 61 patients (gold standard: histopathology). According to the equation "NPV = specificity (1-prevalence) / [specificity (1-prevalence) + (1-sensitivity) prevalence]" FDG PET/CT was evaluated as a triage tool for SLNB versus ALND. The sensitivity, specificity, PPV, NPV and accuracy of FDG PET/CT was 58, 92, 82, 77 and 79% and of CT 46, 89, 72, 71 and 72%, respectively. Patients with an up to approximately 60% risk for axillary lymph node metastases appear to be candidates for SLNB provided that the axilla is unremarkable on FDG PET/CT. FDG PET/CT cannot replace invasive approaches for axillary staging but may extend the indication for SLNB.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.