Abstract

Objective To explore the value of color Doppler echocardiography (CDE) combined with serum heart-type fatty acid-binding protein (h-FABP) and cardiac troponin I (cTnI) in the diagnosis of myocardial infarction and its evaluation value in left ventricular function. Methods A total of 44 patients with myocardial infarction who were treated in Cangzhou Central Hospital from October 2018 to February 2020 were included in the observation group, and 45 healthy subjects were included in the control group. The serum h-FABP and cTnI levels of the two groups were compared and analyzed. The coincidence rate of echocardiography plus serum h-FABP and cTnI for single diagnosis and combined diagnosis was analyzed. The left ventricular function indexes of patients with myocardial infarction in different cardiac function grades were compared, including left ventricular end-diastolic diameter (LVEDD), left ventricular end-systolic diameter (LVESD), left ventricular end-systolic volume (LVESV), left ventricular end-diastolic volume (LVEDV), stroke volume (SV), cardiac index (CI), and the ratio of peak velocity blood flow from left ventricular relaxation in early diastole to peak velocity flow in late diastole (E/A). The value of echocardiography combined with serum h-FABP and cTnI in the left ventricular function in patients with myocardial infarction was analyzed. Results The levels of serum h-FABP and cTnI in the observation group were significantly higher than those in the control group (P < 0.05). CDE plus serum h-FABP and cTnI was associated with significantly higher sensitivity, specificity, and accuracy in diagnosing myocardial infarction versus single detection (P < 0.05). The LVEDV, SV, and CI parameters were similar in patients with different cardiac function grades (P > 0.05). Compared with cardiac function grades I and II, the level of LVEF in patients with myocardial infarction in grades III and IV of cardiac function decreased, while the levels of LVEDD, LVESD, LVESV, and E/A increased (P < 0.05). The levels of serum h-FABP and cTnI in patients with myocardial infarction increased with the increase of cardiac function grades (P < 0.05). Conclusion Patients with myocardial infarction show high levels of h-FABP and cTnI, and CDE plus the detection of serum h-FABP and cTnI levels can significantly improve the detection accuracy and effectively evaluate the left ventricular function of patients with myocardial infarction, with a certain predictive value for cardiac function grading in myocardial infarction.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call