Abstract

Objective To explore the diagnostic value of dynamic enhanced magnetic resonance imaging (MRI) combined with serum CA15-3, CYFRA21-1, and TFF1 for breast cancer. Methods By means of a retrospective study, 60 breast cancer patients treated in our hospital from January 2018 to December 2020 were selected as the breast cancer group, 60 patients with benign breast lesions were selected as the benign group, and 60 healthy individuals who received physical examination in our hospital in the same period were selected as the control group. All study subjects received dynamic enhanced MRI scan and serological tests, their serum CA15-3 and CYFRA21-1 levels were measured with the electrochemiluminescence instrument and original auxiliary reagent, and the TFF1 level was measured with enzyme-linked immunosorbent assay (ELISA). The MRI performance variation in breast lesion patients was analyzed, the serum CA15-3, CYFRA21-1, and TFF1 levels of study subjects were compared among the three groups, and the efficacy of single diagnosis by dynamic enhanced MRI, CA15-3, CYFRA21-1, or TFF1 as well as combined diagnosis was explored by ROC curves. Results Dynamic enhanced MRI showed that malignant lesion had obscure boundary, irregular margin, and heterogeneity after enhancement, and the time-signal intensity curve presented fast-in fast-out; the benign lesion had a clear boundary and smooth margin, 25 cases showed homogeneity after enhancement, and the time-signal intensity curve presented slow-in slow-out; the CA15-3, CYFRA21-1, and TFF1 levels were significantly different among the breast cancer group, benign group, and control group (33.81 ± 12.46 vs 19.02 ± 6.47 vs 9.55 ± 2.64, 4.08 ± 1.41 vs 1.96 ± 1.19 vs 0.99 ± 0.21, 1.39 ± 0.54 vs 1.04 ± 0.26 vs 0.89 ± 0.12, P < 0.05); 57 breast cancer patients were diagnosed by a combined examination, with a sensitivity of 95.0%, specificity of 83.3%, positive predictive value of 74.0%, negative predictive value of 97.1%, accuracy rate of 87.2%, and AUC (95%CI) = 0.892 (0.840–0.943), indicating a significantly higher diagnostic value of the combined examination than the single examination by CA15-3, CYFRA21-1, TFF1, or MRI. Conclusion Combining dynamic enhanced MRI with serum CA15-3, CYFRA21-1, and TFF1 has good efficacy in diagnosing breast cancer, which can be applied in clinical diagnosis of breast cancer.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.