Abstract
Secondary hyperparathyroidism (SHPT) is one of the common complications of end-stage renal disease-uremia, and is mainly manifested as parathyroid hyperplasia and abnormal secretion of parathyroid hormone (PTH). To investigate the value and advantages of contrast-enhanced ultrasound (CEUS) in evaluating the survival of autografts after parathyroidectomy + parathyroid autotransplantation. In this study, 125 patients with renal failure due to polycystic kidney disease, chronic nephritis, diabetic nephropathy, lupus nephritis, and atherosclerotic nephropathy were enrolled as the participants and each of them had 4 secondary hyperactive parathyroid glands and underwent parathyroid autotransplantation. One parathyroid gland was taken from each patient and equally divided into 4 parts and placed in the subcutaneous fat of one forearm for transplantation. CEUS was performed 14 days after the transplantation to observe the micro blood supply of the graft and assess the survival and secretory function of the transplanted parathyroid. The grafts were divided into the partial survival group and the total survival group based on the enhancement characteristics. The survival of the grafts was determined by comparing the parathyroid hormone level in bilateral elbow cephalic veins 1 month after surgery. Among the 125 patients, 112 had linear or punctate enhancement of 2-4 parathyroid glands 14 days after surgery, and 13 patients had linear or punctate enhancement of 0-1 parathyroid gland. There were statistically significant differences in the perfusion pattern, enhancement uniformity, and parathyroid hormone levels in the cephalic veins at the elbow on both the graft and non-graft sides among all groups (P< 0.05). Compared to the detection of the difference in the parathyroid hormone level in the cephalic vein of bilateral elbows 1 month after surgery, CEUS can reflect the parathyroid survival after transplantation more quickly and accurately 2weeks later, and provide a more rapid and agile non-invasive clinical diagnosis method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Technology and health care : official journal of the European Society for Engineering and Medicine
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.