Abstract
BackgroundThe evidence on diagnostic test accuracy (DTA) of diabetic retinopathy (DR) screening utilising photographic studies by non-ophthalmologist personnel in low and middle-income country (LMIC) settings is scarce. We aimed to assess DTA of DR screening using a nonmydriatic hand-held digital camera by trained general physicians in a non-ophthalmic setting.MethodsThis study is a validation of a screening intervention. We selected 700 people with diabetes (PwDM) > 18 years of age, not previously screened or treated for DR, presenting at a tertiary medical clinic in Sri Lanka. Two-field retinal imaging was used to capture fundus images before and after pupil dilatation, using a hand-held non-mydriatic (Visuscout 100®-Germany) digital retinal camera. The images were captured and graded by two trained, masked independent physician graders. The DTA of different levels of DR was assessed comparing physician’s grading with a retinologist’s clinical examination by mydriatic bio-microscopy, according to a locally adopted guideline.ResultsSeven hundred eligible PwDM were screened by physician graders. The mean age of participants was 60.8 years (SD ±10.08) and mean duration of DM was 9.9 years (SD ±8.09). Ungradable image proportion in non-mydriatic imaging was 43.4% (either eye-31.3%, both eyes 12.1%). This decreased to 12.8% (either eye-11.6%, both eyes-1.2%) following pupil dilatation. In comparison to detection of any level of DR, a referable level DR (moderate non-proliferative DR and levels above) showed a higher level of DTA. The sensitivity of the defined referable DR was 88.7% (95% CI 81.7–93.8%) for grader 1 (positive predictive value [PPV] 59.1%) and 92.5% (95% CI 86.4–96.5%) for grader 2 (PPV 68%), using mydriatic imaging, after including ungradable images as screen positives. The specificity was 94.9% (95% CI 93.6–96.0%) for grader 1 (negative predictive value [NPV] 99%) and 96.4% (95% CI 95.3–97.3%) for grader 2 (NPV 99.4%).ConclusionsThe Physicians grading of images from a digital hand-held non-mydriatic camera at a medical clinic, with dilatation of pupil of those who have ungradable images, provides a valid modality to identify referable level of DR. This could be a feasible alternative modality to the existing opportunistic screening to improve the access and coverage.Trial registrationCurrent Controlled Trials ISRCTN47559703. Date of Registration 18th March 2019, Retrospectively registered.
Highlights
The evidence on diagnostic test accuracy (DTA) of diabetic retinopathy (DR) screening utilising photographic studies by non-ophthalmologist personnel in low and middle-income country (LMIC) settings is scarce
In the grading of DR and macular signs, we found that inter-grader agreement was mostly > 0.8 except for the grader 2 non-mydriatic images
Reasons for ungradability of images, prevalence of DR and time and flow of the participants We described the possible reasons for ungradability, using the highest recorded ungradability values, which was observed by grader 1
Summary
The evidence on diagnostic test accuracy (DTA) of diabetic retinopathy (DR) screening utilising photographic studies by non-ophthalmologist personnel in low and middle-income country (LMIC) settings is scarce. We aimed to assess DTA of DR screening using a nonmydriatic hand-held digital camera by trained general physicians in a non-ophthalmic setting. The International Diabetes Federation (IDF) estimated that cases of DM will increase to 629 million by 2045, with a significant burden (80%) in low and middle income countries (LMIC) [2]. The St Vincent declaration stated that all nations should make efforts to reduce DM related complications, including DR blindness [4]. These recommendations were followed by most of the high-income countries (HICs). The LMICs would be able to achieve this aim with the adaptation and use of existing technologies according to the local contextual requirements
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.