Abstract

The purpose of this study was to establish the diagnostic reference levels (DRLs) for paediatric head computed tomography (CT) in Morocco and to assess the effective doses received during head CT examinations. The data of 1007 patients were collected retrospectively from Moroccan university children's hospitals. The sample was classified per age group:<1, 1-5, 5-10 and 10-15 years. The proposed DRLs were defined as 75th percentile of the distributions, which were in terms of CT dose index of 26.98, 28.88, 34.00 and 38.20 mGy and dose length product of 461.64, 540.06, 627.20 and 705.98 mGy.cm, respectively. The effective doses estimated were 3.6, 2.9, 2 and 1.79 mSv, respectively. The DRLs reported in Morocco were compared with those of other countries, which were based on the same age grouping method, including Thailand, Switzerland, Japan and the international DRLs. Our initiative via the determination of the first Moroccan diagnostic reference levels for paediatric head CT must be a starting point to spread this investigation towards other examinations and imaging modalities.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call