Abstract

BackgroundTo investigate and compare the diagnostic performance in T staging for patients with esophagogastric junction cancer using high-resolution magnetic resonance imaging (HR MRI), as compared with conventional MRI at 3 Tesla.MethodsA total of 118 patients with pathologically confirmed esophagogastric junction cancer were included and underwent multiparameter HR MRI (Cohort 1, 62 patients) or conventional MRI (Cohort 2, 56 patients). T2-weighted, T1-weighted, diffusion-weighted and contrast-enhanced T1-weighted images of each patient were evaluated by two radiologists who determined the preoperative T staging by consensus. Using pathologic staging as the gold standard, the consistency between HR MRI and pathology and between conventional MRI and pathology in T staging was calculated and compared. The overall accuracy, overstatement and understatement of HR MRI and conventional MRI in T staging of patients with esophagogastric junction cancer were computed and compared. Moreover, the diagnostic performance of HR MRI and conventional MRI in T staging (≤ T1 and ≥ T4) of patients with esophagogastric junction cancer were evaluated.ResultsThere were no significant differences in age (p = 0.465) and sex (p = 0.175) between Cohorts 1 and 2. Excellent agreement was observed in the T staging of patients with esophagogastric junction cancer between pathology and HR MRI (kappa = 0.813), while moderate agreement was observed between pathology and conventional MRI (kappa = 0.486). Significant differences were observed in overall accuracy (88.7% vs 64.3%, p = 0.002) and understatement (1.6% vs 26.8%, p < 0.001) but not for overstatement (9.7% vs 8.9%, p = 0.889) in T staging between HR MRI and conventional MRI techniques. For differentiating the T stages of ≤ T1 from ≥ T2 and the T stages of ≤ T3 from ≥ T4, no significant differences were observed between the imaging techniques.ConclusionsHR MRI has good diagnostic performance and may serve as an alternative technique in the T staging of patients with esophagogastric junction cancer in clinical practice.

Highlights

  • To investigate and compare the diagnostic performance in T staging for patients with esophagogastric junction cancer using high-resolution magnetic resonance imaging (HR MRI), as compared with conventional MRI at 3 Tesla

  • Only a moderate agreement was observed between pathology and conventional MRI, with a kappa value = 0.486

  • There were significant differences in the overall accuracy (88.7% vs 64.3%, p = 0.002) and understatement (1.6% vs 26.8%, p < 0.001) between HR MRI and conventional MRI techniques in the T staging of patients with esophagogastric junction cancer, but there was no significant difference in overstatement (9.7% vs 8.9%, p = 0.889) in the T staging (Table 4)

Read more

Summary

Introduction

To investigate and compare the diagnostic performance in T staging for patients with esophagogastric junction cancer using high-resolution magnetic resonance imaging (HR MRI), as compared with conventional MRI at 3 Tesla. The prevalence of esophagogastric junction cancer has increased in Western countries and Japan in recent decades [1,2,3]. The T staging of esophagogastric cancer is important for making treatment plans and is a core component of the TNM staging system. Patients with T2-T4a stage cancer may have a chance of undergoing radical surgery and may need neoadjuvant chemoradiotherapy before surgery, depending on the stage. Patients with T4b are not eligible for undergoing surgery [4]. An accurate and efficient method is needed to differentiate these stages and to provide a treatment reference for clinicians

Objectives
Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.