In this paper, the structures of 11 steel welded bridges in Poland are shown. These bridges were constructed between 1929 and 1939. In 7 of those bridges, 15 routine photographic X-ray tests of the butt joints were made. From 136 X-ray pictures, the bad condition of the butt welds and the occurrence of internal cracks in the welds were found. To estimate the future safe usage period of the bridges, examinations of the fatigue strength of the welded butt joints of a similar structure were performed and a stress analysis carried out on them.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.