Abstract

Abstract Funding Acknowledgements Type of funding sources: None. Introduction Atrial fibrillation (AF) is the most common sustained arrhythmia and an important risk factor for stroke and heart. Recent technology advances have allowed for heart rhythm monitoring using smart gadgets/wearable devices which can be used for early AF diagnosis. Purpose We performed a systemic review and meta-analysis to assess the accuracy of AF diagnosis by smart gadgets/wearable devices in primary prevention. Methods We systematically searched Medline, Embase and Cochrane electronic databases up to September 22th, 2022 for observational studies of the diagnostic accuracy of smartphone application, wrist-worn wearables and external devices in detecting AF in primary prevention. Studies with 12-lead ECG or single-lead ECG interpreted by a cardiologist as gold standard were included. We calculated the area under the curve (AUC) of the summary receiver operating characteristic curves (SROC) and pooled sensitivities and specificities. Results A total of 28 studies were included enrolling 13463 patients, 57%(95% CI: 55-59%) male with average age of 65.3years (95% CI: 60.1 – 70.4). The pooled prevalence of AF was found to be 13% (95% CI 10 – 15%). In the overall analysis of all devices, the AUC was 0.99 (95% CI: 0.97-0.99)(Figure 1), the sensitivity 93%(95% CI: 89 – 95%) and the specificity 97%(95% CI: 95 – 98%) (Figure 2). Wrist-worn wearables had AUC of 0.97 (95% CI: 0.94-0.99), the sensitivity 83%(95% CI: 52 – 96%) and the specificity 98%(95% CI: 87 – 100%). Smartphone applications had AUC of 0.97 (95% CI: 0.96-0.98), the sensitivity 92%(95% CI: 77 – 98%) and the specificity 95%(95% CI: 91 – 97%). External devices had AUC of 0.99 (95% CI: 0.97-0.99), the sensitivity 94%(95% CI: 91 – 96%) and the specificity 97%(95% CI: 95 – 98%). Single-lead ECG had AUC of 0.99 (95% CI: 0.97- 0.99), the sensitivity 93%(95% CI: 88 – 96%) and the specificity 91%(95% CI: 78 – 97%). photoplethysmography pulse waveform technology (PPG) had AUC of 0.97 (95% CI: 0.96-0.98), the sensitivity 91%(95% CI: 78 – 97%) and the specificity 95%(95% CI: 91 – 97%). Pulse beat interval technology had AUC of 0.99 (95% CI: 0.98-0.99), the sensitivity 95%(95% CI: 90 – 98%) and the specificity 96%(95% CI: 93 – 98%) Conclusions Smartphone application, wrist-worn devices and external devices have excellent diagnostic accuracy in atrial fibrillation diagnosis in primary prevention.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call