Abstract

Our aim was to investigate the diagnostic accuracy of in vivo micro-CT for osseous abnormalities of the rat temporomandibular joint (TMJ) condyle, using macroscopic observations as the "gold standard". A 30 TMJ arthritis model was prepared by injecting inflammatory complete Freund's adjuvant (CFA) into one side of the TMJ cavities of rats. The TMJ condyles were then imaged using micro-CT. The samples were macroscopically evaluated for osseous abnormalities, including erosions, osteophytes, flattening and concavity. The micro-CT images were independently assessed for abnormalities using the same criteria. Images in three planes were produced using the micro-XYZ technique with the micro-CT equipment. According to the macroscopic observations, 26 of the 60 rat condyles showed osseous abnormalities. The micro-XYZ images detected abnormalities in 25 of the condyles. The condyle diagnostic accuracy of micro-CT was 0.98, the sensitivity was 0.96 and the specificity was 1.0. Good diagnostic results were obtained using micro-CT. It is therefore an effective technique for the evaluation of osseous abnormalities in the rat TMJ condyle.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.