Abstract

The diagnostic accuracy of FDG-PET/CT for the detection of axillary lymph node metastases in breast cancer patients acquired 60 min after FDG administration is reported to be only moderate, especially due to low sensitivity. To test whether a delayed scan 90 min after FDG administration could enhance the diagnostic accuracy of FDG-PET/CT for the detection of axillary lymph node metastases. Thirty-eight women suffering from primary breast cancer (mean age 52 years; range 25-78 years; standard deviation 14 years) underwent a pre-therapeutic dual-time-point FDG-PET/CT scan. The maximum standardized uptake value (SUVmax) of axillary lymph nodes was measured at two different time points (time point T1: 60 min after FDG injection, time point T2: 90 min after FDG injection). SUVmax of axillary lymph nodes at T1 and T2 were assessed for statistical significance using a paired Wilcoxon-Test (P < 0.05). At T1 a qualitative analysis of the FDG-PET/CT scan was performed to define physiologic and metastatic lymph nodes. At T2 an increase of the SUVmax of at least 3.75% over time was rated as indicating malignancy. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and the accuracy of FDG-PET/CT for the detection of axillary lymph node metastases was calculated at time points T1 and T2. Statistically significant differences were determined using Fisher's exact test (P < 0.05). Histopathology served as the standard of reference. A compartment based analysis was done. Axillary lymph nodes had a mean SUVmax of 1.6 (range 0.6-10.8; SD 1.9) at T1 and a mean SUVmax of 1.8 (range 0.5-17.9; SD 3.5) at T2. This difference was statistically significant (P = 0.047). The sensitivity, specificity, PPV, NPV, and accuracy of FDG-PET/CT for the detection of axillary lymph node metastases was 81%, 100%, 100%, 88%, and 92% at T1, and 88%, 50%, 56%, 85%, and 66% at T2, respectively. This difference was not statistically significant (P = 0.27). There is a slight increase of the FDG accumulation of axillary lymph nodes between 60 and 90 min after FDG administration. This increase did not translate into a statistical significant enhancement of the diagnostic accuracy of FDG-PET/CT for the detection of axillary lymph nodes. Especially due to false-positive results a delayed FDG-PET/CT scan 90 min after FDG administration is not able to enhance the diagnostic accuracy for the detection of lymph node metastases.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.