Abstract
To review the published evidence on cone-beam breast computed tomography (CBBCT) and summarize its diagnostic accuracy for breast lesion assessment. A systematic literature search was conducted using the EMBASE, MEDLINE and CENTRAL libraries. Studies were included if reporting sensitivity and specificity for discrimination of benign and malignant breast lesions via breast CT. Sensitivity and specificity were jointly modeled using a bivariate approach calculating summary areas under the receiver-operating characteristics curve (AUC). All analyses were separately performed for non-contrast and contrast-enhanced CBBCT (NC-CBBCT, CE-CBBCT). A total of 362 studies were screened, of which 6 with 559 patients were included. All studies were conducted between 2015 and 2018 and evaluated female participants. Four of six studies included dense and very dense breasts with a high proportion of microcalcifications. For NC-CBBCT, pooled sensitivity was 0.789 (95% CI: 0.66-0.89) and pooled specificity was 0.697 (95% CI: 0.471-0.851), both showing considerable significant between-study heterogeneity (I2 = 89.4%, I2 = 94.7%, both p < 0.001). Partial AUC for NC-CBBCT was 0.817. For CE-CBBCT, pooled sensitivity was 0.899 (95% CI: 0.785-0.956) and pooled specificity was 0.788 (95% CI: 0.709-0.85), both exhibiting non-significant moderate between-study heterogeneity (I2 = 57.3%, p = 0.0527; I2 = 53.1%, p = 0.0738). Partial AUC for CE-CBBCT was 0.869. The evidence available for CBBCT tends to show superior diagnostic performance for CE-CBBCT over NC-CBBCT regarding sensitivity, specificity and partial AUC. Diagnostic accuracy of CE-CBBCT was numerically comparable to that of breast MRI with meta-analyses reporting sensitivity of 0.9 and specificity of 0.72. • CE-CBBCT rather than NC-CBBCT should be used for assessment of breast lesions for its higher diagnostic accuracy. • CE-CBBCT diagnostic performance was comparable to published results on breast MRI, thus qualifying CE-CBBCT as a potential imaging alternative for patients with MRI contraindications.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.