Abstract

The aim of the present study was to assess the diagnostic accuracy of 7 clinical tests for Morton's neuroma (MN) compared with ultrasonography (US). Forty patients (54 feet) were diagnosed with MN using predetermined clinical criteria. These patients were subsequently referred for US, which was performed by a single, experienced musculoskeletal radiologist. The clinical test results were compared against the US findings. MN was confirmed on US at the site of clinical diagnosis in 53 feet (98%). The operational characteristics of the clinical tests performed were as follows: thumb index finger squeeze (96% sensitivity, 96% accuracy), Mulder's click (61% sensitivity, 62% accuracy), foot squeeze (41% sensitivity, 41% accuracy), plantar percussion (37% sensitivity, 36% accuracy), dorsal percussion (33% sensitivity, 26% accuracy), and light touch and pin prick (26% sensitivity, 25% accuracy). No correlation was found between the size of MN on US and the positive clinical tests, except for Mulder's click. The size of MN was significantly larger in patients with a positive Mulder's click (10.9 versus 8.5 mm, p = .016). The clinical assessment was comparable to US in diagnosing MN. The thumb index finger squeeze test was the most sensitive screening test for the clinical diagnosis of MN.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.