Abstract

We aimed to explore the role of the diagnostic accuracy of 18F fluodeoxyglucose PET (18F-FDG PET) or PET/CT for characterization of adrenal lesions through a systematic review and meta-analysis. The MEDLINE, EMBASE, and Cochrane Library database, from the earliest available date of indexing through 30 April 2017, were searched for studies evaluating the diagnostic performance of 18F-FDG PET or PET/CT for characterization of adrenal lesions. We determined the sensitivities and specificities across studies, calculated positive and negative likelihood ratios (LR + and LR-), and constructed summary receiver operating characteristic curves. Across 29 studies (2421 patients), the pooled sensitivity for 18F-FDG PET or PET/CT was 0.91 [95% CI (0.88-0.94)] with heterogeneity (χ2 = 141.8, p = 0.00) and a pooled specificity of 0.91 [95% CI (0.87-0.93)] with heterogeneity (χ2 = 113.7, p = 0.00). Likelihood ratio (LR) syntheses gave an overall positive likelihood ratio (LR+) of 9.9 [95% CI (7.1-13.7)] and negative likelihood ratio (LR-) of 0.09 [95% CI (0.07-0.13)]. The pooled diagnostic odds ratio was 105 [95% CI (63-176)]. In metaregression analysis, study design, publication year, study location (western vs others), interpretation criteria of PET or PET/CT images, quantification of PET or PET/CT [SUVmax (maximum standardized uptake value) vs SUV (standardized uptake value) ratio], patient group, and analysis method (patient-based vs lesion-based) were the sources of the study heterogeneity. However, in multivariate metaregression, no definite variable was the source of the study heterogeneity. 18F-FDG PET or PET/CT demonstrated good sensitivity and specificity for the characterization of adrenal masses. At present, the literature regarding the use of 18F-FDG PET or PET/CT for the characterization of adrenal masses remains still limited; thus, further large multicenter studies would be necessary to substantiate the diagnostic accuracy of 18F-FDG PET or PET/CT characterization of adrenal masses. Advances in knowledge: 18F- FDG PET or PET/CT showed good sensitivity and specificity for the characterization of adrenal masses and could provide additional information for that purpose.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.