Abstract

Gastrointestinal (GI) bleeding scintigraphy in combination with single-photon emission computed tomography/computed tomography (SPECT/CT) remains to be studied in detail. This study aimed to examine the diagnostic ability of this tool. GI bleeding scintigraphy using (99m)Tc-human serum albumin-diethylenetriaminepentaacetic acid was performed for 38 patients with suspected GI bleeding. Twenty-four patients were diagnosed using planar images alone (planar group) and 14 patients were diagnosed using planar images and additional SPECT/CT images (planar + SPECT/CT group). The diagnostic ability of each method was analyzed. GI bleeding was observed in 20 of the 38 patients. For the existence of GI bleeding, planar images alone showed a sensitivity of 70%, specificity of 93%, positive predictive value (PPV) of 88%, negative predictive value (NPV) of 81%, and an overall accuracy of 83%, whereas planar images + SPECT/CT showed a sensitivity of 100%, specificity of 75%, PPV of 91%, NPV of 100%, and an overall accuracy of 93%. The source of bleeding was accurately diagnosed in 50% in the planar group and 78% in the planar + SPECT/CT group. In the planar + SPECT/CT group, 44% of the evaluable patients showed correct localization of the source of GI bleeding by additional SPECT/CT images, although planar images only showed incorrect localization. GI bleeding scintigraphy in combination with SPECT/CT is a noninvasive and useful tool for the examination of GI bleeding.